Air scissor lift Six emergency treatment

     An electrolyte splashed on skin: Flush with plenty of water
     2, electrolyte splashed in the eyes: Electric Hand Pallet Jacks rinse with plenty of water, and then receive professional medical treatment
     3, the electrolyte spilled into clothes: immediately took off his clothes, rinse with water and then rinse with a weak alkaline soap.
     4, electrolyte leakage: the electrolyte leakage to the outside immediately with lime, palle stackers strong carbonated soda or carbonated soda to neutralize etc., and rinse with plenty of water.

2015年2月11日星期三

liftstar hand pallet truck Electric Stacker repair and maintenance mainly the following considerations

Electric Stacker repair and maintenance mainly the following considerations: the battery charging and maintenance, repair and maintenance of the battery, the mechanical part of the repair and maintenance
Battery charging and maintenance:
The main parameters of the vehicle pallet jacks charger provides as follows:
Input: AC 220V / 50HZ
Output: Voltage: DC24V
Current: DC0 ~ 30A
Before charging off batteries and control part of the circuit (press the red emergency stop button), and then the charger output plug-in access to the car charging jack, plug the charger plug in the AC 220V, 50HZ power outlet, at the end of the charge , first unplug the AC power cord. Plug the plug of the order must be strictly adhered to. See detailed instructions manual charger.
  Note:
At least once a week to check the electrolyte palle stackers fluid level.
Electrolyte supplements should be carried out after the end of charge, since the electrolyte during charging swell. As the liquid level is too low, the need for more than one hour after the end of charge in order to add distilled water (or deionized water).
Battery surface should be kept clean and dry, because dirt and moisture may cause leakage and lead to decreased battery capacity. Available electrolyte leakage soda solution or dilute ammonia and then rinse with water, please.
Line column joints to fully tighten the oil and coated with acid to avoid sulfide layer. Sulfide layer reduce the contact surface resulting in a considerable voltage drop objective.
Censorship:
Detect the battery state of charge every day acid hydrometer (electro-hydraulic hydrometer). It should not discharge the battery to the gravity of less than 1.16. (Ninety percent discharge)
The proportion at 30 ℃ Electric Hand Pallet Jacks charging status
1.260 ~ 1.280 100%
1.230 ~ 1.250 75%
1.200 ~ 1.220 50%
1.170 ~ 1.190 25%
1.140 ~ 1160 has discharged 90%

2014年6月16日星期一

Stacker drive wheel drive motor speed significantly reduced or severe overload Cause


The battery voltage is too low or too big pile head contact resistance; between the motor commutator segments coke cause a short circuit between the chip; motor improperly adjusted brakes with brake leaving the motor running; drive head gear boxes and bearings lack of lubrication or chassis card motor armature short circuit; resistance.
Solution: Check the battery terminal voltage Stacker load or cleaning trailer coupling; clean up the commutator; adjust the brake clearance; checking cleaning and re-filling oil, remove Electric Hand Pallet Jacks jamming phenomenon; replace the new motor.Stacker crane lifting weakness or not
Reason: Gear pumps and pump mention excessive wear; improper high-pressure relief valve inside; oil pipeline spill; hydraulic oil temperature over; mast carriage
jamming phenomenon exists; pump motor speed is too low.
Solution: Replace worn or gear pump; readjust; inspection and repair; replace defective hydraulic oil and drum trucks the oil temperature rise causes; Check and adjust; Check the motor and troubleshooting.
piled high door frame automatically tilt difficulties or action not smooth
Cause: The tilt cylinder wall and seals for excessive wear; within the valve stem spring failure; piston rod stuck in the cylinder wall or bent; within the tilt cylinder seals fouling too much or too compressed.
Solution: Replace the O-rings or cylinders; replace qualified spring; replace damaged parts; cleaning adjustments.